Technical specifications

last modified 08-02-2008 16:14


operational

Sept. 1994

scientific applications
XAS, Surface XAS, WAXS, AWAXS
source characteristics
bending magnet ec = 19.2 keV

source size 0.187 x 0.128 mm2 (HxV) FWHM

source divergence 115 x 5 µrad2 (HxV) FWHM

divergence for photon source(ec) dF =3.6 mrad, sR=50 µrad

peak brightness 7·1013 ph s-1mrad-2 (0.1% bw, 0.1A)

power (from 3.6 mrad of the source) 225 W FWHM

power density at 25 m 0.83 Wmm-2 FWHM

beam size at 25m 90 x 3 mm2 (HxV) FWHM

total horiz. ang. acceptance 3.6 mrad

optics

optical elements: mirror 1* double-crystal mono. mirror 2*

distance from source: 25 m 28.5 m 32 m

focusing type: vert. coll. horiz. foc. vert. foc.

*mirrors only used for low energy set-up (5-28 keV)

beam size at sample: 1 x 2 mm2 (HxV) for 5 - 28 keV

1 x 2 mm2 (HxV) for 28 - 50 keV

spectral range: 5 - 85 keV

energy resolution DE/E: 10-5 - 10-4

flux at sample: 1010 - 1011 ph s-1 (0.01%bw, 0.1A)

detectors

see text

European Synchrotron Radiation Facility