DPAP 2 setting 1

last modified 10-09-2008 15:30
DPAP 2 setting 1

When you want to configure a DPAP module for use with a stepper motor, you must :
- know the phase current
- know the positive direction

Current settings :
Current Table for DPAP2
Current Table for DPAP1

You can adjust the phase current by turning the 3 rotary switches:
Normal : normal phase current
Boost : phase current during the boost cycle
Off : holding current (phase current at rest)

Switch setting :
If you have the wrong polarity for the limit switches (both limits led are on), you must
change the two jumpers W2 and W3.
W2 : Polarity change for the CW limit switch
W3 : Polarity change for the CCW limit switch

Motor direction :
When you move the motor in the positive direction, you must hit the CW hard limit.
If not, you have to change the jumper W15.
If the positive direction, according to the limit, is not correct, you must change
the wiring in the motor connector itself.

Continuity Wiring Control :
If the led C, on the front panel, is on, change the jumper W4.