You are here: Home Users and Science Experimental facilities Find a beamline

Beamline Snapshot


ID21


X-ray Microscopy Beamline

Scanning X-ray microscope (SXM) / Fourier-transform infrared microscope (FTIR)


ID21 comprises two endstations: (a) a scanning X-ray microscope (2-9 keV) optimized for X-ray micro-fluorescence and micro-spectroscopy imaging of elemental distributions and chemical speciation of samples (sub-micron lateral resolution), and (b) an endstation devoted to infrared spectro-microscopy in the mid-infrared range.

Disciplines

  • Medicine
  • Cultural Heritage
  • Environmental Sciences
  • Earth and Planetary Sciences
  • Materials and Engineering
  • Physics
  • Life Sciences
  • Chemistry

Applications

  • Archeometry (e.g. pigments, glasses)
  • Biology (e.g. nano-toxicology, pathology, metallobiology, health)
  • Geochemistry (e.g. basaltic glasses, sediments)
  • Environmental sciences (e.g. soils, phytoremediation, pollution)
  • Materials (e.g. nano-materials, energy)

  Energy range
  2.1-9.2 keV

 Beam size
  Minimum (H x V)
  0.7 x 0.3 µm2
  Maximum (H x V)
  2 x 2 mm2


Beamline home page


Status

open


Contacts

Marine Cotte
Scientist in charge of beamline
cotte@esrf.fr
+33 (0)4.76.88.21.27

Murielle Salome
Beamline operation manager
salome@esrf.fr
+33 (0)4.76.88.22.10






 

Techniques

  • XANES - X-ray absorption near-edge structure
  • XRF - X-ray fluorescence
  • FTIR - Fourier transform infrared spectroscopy/microscopy
  • microXRF - micro X-ray fluorescence
  • microXANES - micro X-ray absorption near-edge structure

Sample environments

  • SXM:
  • - In vacuum operation
  • - Cryo-stage
  • - Wet cell
  • FTIR:
  • - Diamond micro-compression cell

Detectors

  • SXM endstation (2.1 - 9.2 keV, 0.7 x 3 μm to 2 x 2 mm [hxv]):
  • - Si photodides
  • - Röntec XFlash 2001 10mm2 Silicon Drift Diode
  • - Bruker XFlash 5100 80mm2 Silicon Drift Diode
  • - Princeton Gamma Tech 50mm2 HpGe detector
  • - Princeton Gamma Tech 7 x 50 mm2 multi-element HpGe
  • - Compact wavelength dispersive spectrometer
  • FTIR endstation (700 - 4000 cm-1, 5 x 5 μm to 15 x 15 μm [hxv]):
  • - Thermo Nicollet Nexus infrared spectrometer
  • - Thermo Nicollet Continuum infrared microscope (acquisition in transmission, reflection, attenuated total reflectance [ATR] mode)
  • - MCT 50 microns

Technical details

Beamtime proposals can request access to both ID21 endstations (SXM + FTIR) or to one only.

 

Update beamline data (internal access only)

 

European Synchrotron Radiation Facility