You are here: Home X-ray Source Performance Insertion Devices

Insertion Devices

last modified 23-11-2009 15:23

 

A list of the Insertion Devices and segments in operation as well as a list of the  planned refurbishment  are presented below:

Brilliance of a selection of Insertion Devices


Insertion Devices & Segments


Beamline
ID Type
Period
[mm]

Length
[m]

Max Field [T]
Anomalous scattering
ID1
Undulator
35
1.6
0.7
Undulator
35
1.6
0.7
Undulator
42
1.6
0.83
High Brilliance
ID2
Undulator
24.6
1.6
0.24
Undulator
42
1.6
0.57
Undulator
21.4
1.6
0.4
Surface Diffraction
ID3
Undulator
42
1.6
0.57
Undulator
35
1.6
0.7
Undulator
35
1.6
0.7
Test beamline ID6
CPMU
18
2
0.92
Undulator
34
1.6
0.75
Polarisation dependent Soft X-Ray spectroscopy
ID8
Helical Undulator
88
1.6
0.62 / 0.56
Helical Undulator
88
1.6
0.62 / 0.56
Time resolved
High pressure
ID9
In-vacuum undulator
20
2
0.93
In-vacuum undulator
17
2
0.56

High resolution X-ray scattering - Surface diffraction - X-ray photon correlation - Spectroscopy

ID10
Undulator
35
1.6
0.7
Revolving undulator
27
35
1.6
1.6
0.54
0.7
Undulator
27
1.6
0.54
Material Science
 
ID11
 
In-vacuum undulator
23
1.6
0.9
In-vacuum undulator
22
2
0.87
Circular Polarisation
 
 
ID12
 
 
Helical undulator
80
1.6
0.2/0.2
Helical undulator
52
1.6
0.4/0.4
Helical undulator
38
1.6
0.48/0.3
Microfocus
 
ID13
 
Undulator
46
1.6
0.68
In-vacuum undulator
18
2
0.6
Macromolecular Crytallography
 
 
ID14
 
 
Undulator
42
1.6
0.57
Undulator
24.4
1.6
0.23
Undulator
23
1.6
0.24
High Energy Scattering
 
ID15
 
Asymmetric wiggler
230
1.6
1.9
In-vacuum undulator
22
2
0.87
Inelastic Scattering
 
 
ID16
 
 
Undulator
35
1.6
0.7
Revolving Undulator
26
32
1.6
1.6
0.52
0.64
Revolving Undulator

26
32

1.6
1.6
0.52
0.64
BioMedical
ID17
Wiggler
150
1.6
1.57
Nuclear Resonance
 
 
ID18
 
 
Undulator
32
1.6
0.64
Revolving Undulator
20 1.6 0.32
27
1.6
0.54
Revolving Undulator
20 1.6 0.32
27
1.6
0.54
High Resolution Diffraction
Topography
 
ID19
 
 
Undulator
32
1.6
0.64
Wiggler
150
1.1
1.54
Undulator
32
1.6
0.64
Magnetic Scattering
 
 
ID20
 
 
Undulator
35
1.6
0.7
Undulator
35
1.6
0.7
Undulator
32
1.6
0.64
X-Ray Microscopy
 
 
ID21
 
 
Undulator
40
1.6
0.8
Wiggler
80
1.6
0.81
Undulator
42
1.6
0.57
Micro-Fluorescence Imaging
& Diffraction
ID22
 
Undulator
42
1.6
0.57
In-vacuum undulator
23
2
0.75
Macromolecular Crystallography
ID23
 
Undulator
20.2
1.6
0.36
Undulator
35
1.6
0.7
Dispersive EXAFS
 
ID24
 
Undulator
42
1.6
0.57
Undulator
27
1.6
0.54
Undulator
32
1.6
0.64
High Brilliance
X-Ray Spectroscopy
 
ID26
 
 
Undulator
40
1.6
0.8
Undulator
35
1.6
0.7
Undulator
35
1.6
0.7
High Pressure
 
ID27
 
In-vacuum undulator
23
2
0.75
In-vacuum undulator
23
2
0.75
Inelastic Scattering
 
 
ID28
 
 
Undulator
32
1.6
0.64
Revolving Undulator
17.6 1.6 0.28
32
1.6
0.64
Revolving Undulator
17.6 1.6 0.28
32
1.6
0.64
Multiple wavelength Anomalous
Diffraction (MAD)
ID29
 
Undulator
35
1.6
0.45
In-vacuum undulator
21
2
0.69
Machine
ID30
Undulator
42
1.6
0.57
Undulator
42
1.6
0.57
Undulator
42
1.6
0.57
High Resolution
Powder Diffraction
 
ID31
 
 
Undulator
32
1.6
0.64
Undulator
32
1.6
0.64
Undulator
35
1.6
0.7
Surface & Interface
(X-Ray diffraction)
X-Ray Standing Waves
X-Ray Photoelectron Spectroscopy
ID32
 
 
Undulator
42
1.6
0.83
Undulator
35
1.6
0.7
Undulator
35
1.6
0.7

 

as of 18/09/2008

 

Planned ID refurbishement


Beamline
ID Type
Period
[m]
Length
[m]
Max Field [T]
Nuclear Resonance
ID18
Revolving Undulator
20 1.6 0.32
27
1.6
0.54
Revolving Undulator
20 1.6 0.32
27
1.6
0.54
Revolving Undulator
20
1.6
0.32
27
1.6
0.54
Inelastic Scattering
ID28
Revolving Undulator
17.6 1.6 0.28
32
1.6
0.64
Revolving Undulator
17.6 1.6 0.28
32 1.6
0.28
Revolving Undulator
17.6 1.6 0.28
32 1.6
0.28

Micro-fluorescence Imaging & Diffraction

ID22
Revolving Undulator
19 1.6 0.3
35
1.6
0.7
In-VacuumUndulator
23
2
0.75
 
 High Brilliance
ID2
 
Undulator
21.4
1.6
0.39
Undulator
21.4
1.6
0.39
Undulator
35
1.6
0.7
 
High Resolution Diffraction
Topography
ID19
Revolving Undulator
17.6 1.6 0.28
32
1.6
0.64
Wiggler
150
1.1
1.54
High Brilliance
X-Ray Spectroscopy
ID26 Undulator 35 1.6 0.7
Revolving Undulator 27 1.6 0.54
35 1.6 0.7
Undulator 35 1.6 0.7
Dispersive EXAFS ID24 Undulator 27 1.6 0.54
Undulator 27 1.6 0.54
Undulator 32 1.6 0.64
Test beamline ID6
CPMU
18
2
0.92
Undulator 35 1.6 0.7

 

 

 

Undulator Short period device with nearly sinusoidal vertical field
Helical Undulator
Device combining vertical & horizontal fields, the 1st (2nd) value in the maximum fied column corresponds to the maximum field for each field component in the vertical (horizontal) plane.






Revolving Undulator Device equipped with two undulators mounted on rotative girders






In-vacuum Undulator
Device with magnet assembly inside ultra-high vacuum. It can be operated at a minimum magnetic gap of 6 mm.










CPMU
In-vacuum undulator based on NDFeB permanent magnet material cryogenically cooled at 150K





Wiggler


Device with large period and high field. The X-ray output is smooth as for bending magnet type.





Assymetric wiggler

Wiggler with non symmetric field. The amplitude of positive and negative peaks of the field are strongly different. Provides circular polarization off axis vertically at high x-ray energy




 


European Synchrotron Radiation Facility